DIN Standards Committee Electrical Engineering
VG 96903-80
Nuclear electromagnetic pulse (NEMP) and lightning protection - Test methods, test equipment and limits - Part 80: Testing of antenna terminals against NEMP and lightning disturbance (Test method LF 80); Text in German and English
Schutz gegen Nuklear-Elektromagnetischen Impuls (NEMP) und Blitzschlag - Prüfverfahren, Prüfeinrichtungen und Grenzwerte - Teil 80: Prüfung von Antennenanschlüssen gegen NEMP- und Blitz-Störgrößen (Verfahren LF 80); Text Deutsch und Englisch
Overview
This document applies to equipment to be newly developed or procured for, or to be furnished to the Bundeswehr. It is also applicable to the modernisation of equipment already introduced. The document specifies requirements for the protection against the effects of an exo-NEMP and lightning.When applying this test method, the NEMP respectively lightning test disturbances are fed directly into the antenna terminals of the transmitting and/or receiving systems with the associated antenna matching devices and protection circuits when the antenna is disconnected. The test method according to this document is only applicable if the protection circuits are located in the path behind the antenna. The test method is not applicable to antennas with integrated protective circuitry. In these cases, the test method SF 50 according to VG 96903-50 is applicable. Working Committee NA 140-00-19 AA "Nuklear-Elektromagnetischer Puls (NEMP) und Blitz" ("Nuclear electromagnetic pulse (NEMP) and lightning protection") at DIN Standards Committee Electrical Engineering (NE) is responsible for this document.
Responsible national committee
NA 140-00-19 AA - Nuclear electromagnetic pulse (NEMP) and lightning protection