DIN EN 61675-1
Radionuclide imaging devices - Characteristics and test conditions - Part 1: Positron emission tomographs (IEC 61675-1:2013); German version EN 61675-1:2014

Title (German)

Bildgebende Systeme in der Nuklearmedizin - Merkmale und Prüfbedingungen - Teil 1: Positronen-Emissions-Tomographen (IEC 61675-1:2013); Deutsche Fassung EN 61675-1:2014

Overview

The International Standard has been prepared in IEC/SC 62C "Equipment for radiotherapy, nuclear medicine and radiation dosimetry". The standard specifies terminology and test methods for declaring the characteristics of positron emission tomographs. Positron emission tomographs detect the annihilation radiation of positron emitting radionuclides by coincidence detection. No test has been specified to characterize the uniformity of reconstructed images, because all methods known so far will mostly reflect the noise in the image. Further developments of POSITRON EMISSION TOMOGRAPHS allow most of the tomographs to be operated in fully 3D acquisition mode. To comply with this trend, this standard describes test conditions in accordance with this acquisition characteristic. In addition, today a POSITRON EMISSION TOMOGRAPH often includes X -RAY EQUIPMENT for COMPUTED TOMOGRAPHY (CT). For this standard PET-CT hybrid devices are considered to be state of the art, dedicated POSITRON EMISSION TOMOGRAPHS not including the X-ray component being special cases only. While the test methods specified herein are optimized for the PET component of PET-CT hybrid devices, they may also be used for the PET component of PET-MR hybrid devices. The test methods specified in this standard have been selected to reflect as much as possible the clinical use of POSITRON EMISSION TOMOGRAPHS. It is intended that the tests be carried out by MANUFACTURERS, thereby enabling them to declare the characteristics of POSITRON EMISSION TOMOGRAPHS in the ACCOMPANYING DOCUMENTS. This standard does not indicate which tests will be performed by the MANUFACTURER on an individual tomograph or which class-standards may be used to characterize the performance of POSITRON EMISSION TOMOGRAPHS by the MANUFACTURER. The responsible German committee is Joint Committee NAR/DKE NA 080-00-13 GA "Nuklearmedizin" ("Nuclear medicine") in collaboration with Deutsche Röntgengesellschaft (German Radiological Society).

Document: references other documents

Responsible national committee

NA 080-00-03 AA - Nuclear medicine  

Edition 2016-08
Original language German
Price from 117.70 €
Table of contents

Contact

Alexandra Hannawald

Alexander-Wellendorff-Str. 2
75172 Pforzheim

Tel.: +49 7231 9188-21

Send message to contact