NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Standards [CURRENT]

DIN EN IEC 61753-021-02
Fibre optic interconnecting devices and passive components - Performance standard - Part 021-02: Single-mode fibre optic connectors terminated as pigtails and patchcords for category C - Controlled environment (IEC 61753-021-02:2023); German version EN IEC 61753-021-02:2023

Title (German)

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil 021-02: Lichtwellenleiter-Steckverbinder der Stufe C/2 für Einmodenfasern für die Kategorie C - Kontrollierte Umgebung (IEC 61753-021-02:2023); Deutsche Fassung EN IEC 61753-021-02:2023

Overview

This part of IEC 61753 defines the minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorized as meeting the IEC standard category C (controlled environment), as defined in IEC 61753-1. The standard describes the test setup, pre-treatment, test conditions, monitoring, recovery time, final measurement, test severity, and measurement uncertainties, as well as details of the test report. There are no restrictions on the scope of application of the document. The standard differs from DIN EN 61753-021-2:2008-09 as follows: a) changed scope to remove restrictions on attenuation and return loss grades; b) included provisions for rectangular ferrule connectors; c) changed the terms and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion; d) updated fibre naming conventions according to IEC 60793-2-50 and added provisions for B-657 fibres; e) added all the attenuation and return loss grades defined in IEC 61753-1; f) test severities updated according to IEC 61753-1; g) reduced flexing of strain relief cycles from 100 cycles to 50 cycles; h) added the torsion test; i) reduced the duration of the fibre/cable retention test on reinforced cables from 120 s to 60 s minimum; j) removed the static side load test; k) reduced the number of mating durability cycles from 500 cycles to 200 cycles and added provisions for rectangular ferrule connectors; l) added Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests. The standard increases investment security for manufacturers and users through its application, provides testing laboratories and manufacturers with defined specifications for testing, and ensures compatibility across manufacturers.

Document: references other documents

Responsible national committee

DKE/UK 412.7 - LWL-Verbindungstechnik und passive optische Komponenten  

Edition 2024-06
Original language German
Price from 115.70 €
Table of contents

Contact

Thomas Sentko

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-209

Send message to contact