DIN EN IEC 62321-3-4 ; VDE 0042-1-3-4:2024-06
Determination of certain substances in electrotechnical products - Part 3-4: Screening - Phthalates in polymers of electrotechnical products by high performance liquid chromatography with ultraviolet detector (HPLC-UV), thin layer chromatography (TLC) and thermal desorption mass spectrometry (TD-MS) (IEC 62321-3-4:2023); German version EN IEC 62321-3-4:2023

Title (German)

Verfahren zur Bestimmung von bestimmten Substanzen in Produkten der Elektrotechnik - Teil 3-4: Screening von Phthalaten in Polymeren von Produkten der Elektrotechnik durch Hochleistungs-Flüssigkeitschromatographie mit Ultraviolettdetektor (HPLC-UV), Dünnschichtchromatographie (TLC) und Thermodesorptions-Massenspektroskopie (TD-MS) (IEC 62321-3-4:2023); Deutsche Fassung EN IEC 62321-3-4:2023

Overview

This part of IEC 62321 specifies procedures for the screening of di-isobutyl phthalate (DIBP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), di-(2-ethylhexyl) phthalate (DEHP) in polymers of electrotechnical products by using high performance liquid chromatography with ultraviolet detector (HPLC-UV), thin layer chromatography (TLC) and thermal desorption mass spectrometry (TD-MS). High performance liquid chromatography with ultraviolet detector (HPLC-UV), thin layer chromatography (TLC) and thermal desorption mass spectrometry (TD-MS) techniques are described in the normative part of this document. Fourier transform infrared spectroscopy (FT-IR) is described in the informative annexes of this document. These test methods have been evaluated by testing polyethylene (PE), polyvinyl chloride (PVC) materials containing individual phthalates between 500 mg/kg to 3 000 mg/kg as depicted in the normative and informative parts of this document. The use of the methods described in this document for other polymer types, phthalate compounds or concentration ranges other than those specified above has not been specifically evaluated. The document does not address any specific requirements. The HPLC-UV and TLC techniques are suitable for screening and semi-quantitative analysis of DIBP, DBP, BBP and DEHP in polymers that are used as parts in electrotechnical products above 300 mg/kg. Theu TD-MS technique is suitable for screening and semi-quantitative analysis of DIBP, DBP, BBP and DEHP in polymers that are used as parts in electrotechnical products above 300 mg/kg. The FT-IR technique is suitable for preliminary screening of total phthalates (DIBP, DBP, BBP, DEHP and so forth) in polymers that are used as parts in electrotechnical products above 50 000 mg/kg.

Document: references other documents

Responsible national committee

DKE/K 135 - Erfassung von Stoffen in Produkten der Elektrotechnik  

Edition 2024-06
Original language German