NA 022

DKE German Commission for Electrical, Electronic & Information Technologies of DIN and VDE

Standards [CURRENT]

DIN EN 60079-11 ; VDE 0170-7:2012-06
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" (IEC 60079-11:2011 + Cor.:2012); German version EN 60079-11:2012

Title (German)

Explosionsgefährdete Bereiche - Teil 11: Geräteschutz durch Eigensicherheit "i" (IEC 60079-11:2011 + Cor.:2012); Deutsche Fassung EN 60079-11:2012

Overview

This part of VDE 0170 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended for connection to intrinsically safe circuits which enter such atmospheres. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion in the surrounding explosive atmospheres. This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another type of protection listed in DIN EN 60079-0 (VDE 0170-1), where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are evaluated for use in such an atmosphere by applying this standard. The requirements for intrinsically safe systems are provided in DIN EN 60079-25 (VDE 0170-10-1). This standard supplements and modifies the general requirements of DIN EN 60079-0 (VDE 0170-1), except as indicated in Table 1 of DIN EN 60079-25 (VDE 0170-10-1). Where a requirement of this standard conflicts with a requirement of DIN EN 60079-0 (VDE 0170-1), the requirements of this standard shall take precedence. If requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus the term "apparatus" is used throughout this standard. This standard is for electrical equipment only; therefore the term "equipment" used in this standard always means "electrical equipment". If associated apparatus is placed in the explosive atmosphere, it shall be protected by an appropriate type of protection listed in IEC 60079-0 (VDE 0170-1) , and then the requirements of that method of protection together with the relevant parts of DIN EN 60079-0 (VDE 0170-1). also apply to the associated apparatus. The responsible committee is K 241 "Schlagwetter- und explosionsgeschützte elektrische Betriebsmittel" ("Electrical apparatus for potentially explosive atmospheres") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Document: references other documents

Document: referenced in other documents

Responsible national committee

DKE/K 241 - Schlagwetter- und explosionsgeschützte elektrische Betriebsmittel  

Edition 2012-06
Original language German
Price from 208.67 €
Table of contents

Contact

Dipl.-Ing.

Heike Arnold

Merianstraße 28
63069 Offenbach am Main

Tel.: +49 69 6308-246
Fax: +49 69 6308-9246

Send message to contact