Project

Fibre optic interconnecting devices and passive components - Connector optical interfaces for enhanced macro bend multimode fibre - Part 3-81: Connector parameters of physically contacting 50 µm core diameter fibres - Non-angled polyphenylene sulphide rectangular ferrules with a single row of 12, 8, 4, or 2 fibres for reference connector applications

Abstract

This part of the IEC 63267 series defines the dimensional limits of an optical interface for reference connectors with rectangular ferrules necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connectors with rectangular ferrules intended to be used for attenuation measurements as defined in IEC 63267-2-2. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic interface standards. One grade of reference connector is defined in this document. The reference connector is terminated to restricted IEC 60793-2-10 A1-OM2b to A1-OM5b fibre at 850 nm band only. The geometrical dimensions and tolerances of the specified reference connector have been developed primarily to limit the variation in measured attenuation between multiple sets of two reference connectors, and therefore to limit the variation in measured attenuation between randomly chosen reference connectors when mated with connectors in the field or factory.

Begin

2026-07-09

Planned document number

DIN EN IEC 63267-3-81/A1

Project number

02233995

Responsible national committee

DKE/UK 412.7 - LWL-Verbindungstechnik und passive optische Komponenten  

Contact

Thomas Sentko

Merianstr. 28
63069 Offenbach am Main

Tel.: +49 69 6308-209

Send message to contact