Testing fresh concrete - Part 14: Invert cone flow time
Abstract
This document specifies the procedures for determining the flow time using an inverted cone. NOTE 1 This test was originally developed for tremie concrete. This test can generally be suitable for concretes with a slump test value (measured according to EN 12350-2) higher than 150mm, or concrete with a flow table test value (measured according to EN 12350-5) higher than 450mm. This test doesn't apply to self-compacting concrete. NOTE 2 Self-compacting flow time can be measure using EN 12350-9. This test is not suitable when the maximum size of the coarse aggregate (Dmax) exceeds 22,4 mm.
Begin
2025-09-01
WI
00104473
Planned document number
DIN EN 12350-14
Project number
00520036
Responsible national committee
NA 005-07-05 AA - Test methods for concrete
Responsible european committee
CEN/TC 104/SC 1 - Concrete - Specification, performance, production and conformity