Project

Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 7: Focal spot reconstruction technique

Abstract

This European standard specifies a method for the measurement of effective focal spot dimensions below 0,1 mm of X-ray systems by means of the reconstruction technique, applied to digital images taken from hole type or disk type gauges. The imaging quality and the resolution of X-ray images depends highly on the characteristics of the effective focal spot, in particular the size and the two-dimensional intensity distribution as seen from the detector plane. This method can also be applied for the measurement of effective focal spot dimensions above or equal to 0,1 mm, but the application of the pin hole method of EN 12543-2 is preferable. This document provides instructions for determining the effective size (dimensions) of mini and micro focal spots of industrial X-ray tubes for users in applications where the pin hole method of EN12543-2 is not practicable. This determination is based on the measurement of profiles of an image of a hole or disk type gauge and the reconstruction of the 2D distribution. The use of the pin hole method (ASTM E 1165, EN 12543-2) requires the application of special pin hole cameras. This procedure describes, how the 2D spot shape and size of focal spots can be determined from hole or disk exposures, which are easier to produce in comparison to pin holes and the related cameras. Microfocus (1 μm ≤ spot sizes < 0,1mm) and nanofocus tubes (spot sizes < 1 μm) have a significantly lower photon flux than mini and macro focus tubes (spot sizes ≥ 0.1 mm). Furthermore, pin holes (see EN 12543-2 or ASTM E 1165) with diameters in the nm and μm region are difficult to manufacture and will not permit a sufficient photon statistic for digital imaging with the required magnifications. Nano- and micrometre pin hole methods would require very long exposure times for obtaining a sufficient SNR and CNR

Begin

2023-12-11

WI

00138296

Planned document number

DIN EN 00138296

Project number

06236659

Responsible national committee

NA 062-08-22 AA - Industrial radiation methods  

Responsible european committee

CEN/TC 138/WG 1 - Radiographic testing  