• Hydrogen Technologies Standards form the basic framework for market ramp-up

    More information
  • Climate change Standards and specifications support climate targets

    More information
  • Smart Farming Standards and specifications are drivers for the digitalization of agriculture

    More information
Standards [CURRENT]

DIN 54187
Non-destructive testing - Active thermography with relative motion

Title (German)

Zerstörungsfreie Prüfung - Aktive Thermografie mit Relativbewegung

Overview

This document specifies how active thermography test methods are to be used when there is relative motion between the test system and the test object. The test is used to detect irregularities such as delamination, cavities, cracks, faulty bonding, and the like. The type of defects that can be detected depends on the type of thermal excitation. The corresponding test method without relative motion serves as a decision-making aid for their selection. The same applies to any safety instructions and to the evaluation of the test. In the case of laser excitation, there are additional test techniques with and without relative motion that are covered in DIN EN 17501. This document has been prepared by Working Committee NA 062-11-16 AA "Thermografische Prüfung" ("Thermographic testing") at DIN Standards Committee Materials Testing (NMP).

Responsible national committee

NA 062-11-16 AA - Thermographic testing  

Edition 2024-11
Original language German
Price from 97.40 €
Table of contents