DIN VDE 0100-444
; VDE 0100-444:2010-10
|
2010-10
|
Low-voltage electrical installations - Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances (IEC 60364-4-44:2007 (Clause 444), modified); German implementation HD 60364-4-444:2010 + Cor.:2010
More
|
|
DIN VDE 0100-450
; VDE 0100-450:1990-03
|
1990-03
|
Erection of power installation with nominal voltages up to 1000 V; protective measure for safety; protection against undervoltage
More
|
|
DIN VDE 0100-460
; VDE 0100-460:2018-06
|
2018-06
|
Low-voltage electrical installations - Part 4-46: Protection for safety - Isolation and switching; German implementation of HD 60364-4-46:2016 + A11:2017
More
|
|
DIN VDE 0100-510
; VDE 0100-510:2014-10
|
2014-10
|
Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules (IEC 60364-5-51:2005, modified); German implementation HD 60364-5-51:2009 + A11:2013
More
|
|
DIN VDE 0100-520
; VDE 0100-520:2023-06
|
2023-06
|
Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems (IEC 60364-5-52:2009, modified + Corrigendum Feb. 2011); German implementation HD 60364-5-52:2011 + A12:2022
More
|
|
DIN VDE 0100-520 Beiblatt 1
; VDE 0100-520 Beiblatt 1:2016-10
|
2016-10
|
Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems; Supplement 1: Explanation for application of the normative requirements of DIN VDE 0100-520 (VDE 0100-520):2013-06
More
|
|
DIN VDE 0100-520 Beiblatt 3
; VDE 0100-520 Beiblatt 3:2012-10
|
2012-10
|
Low-voltage electrical installations - Selection and erection of electrical equipment - Part 520: Wiring systems - Supplement 3: Current-carrying capacity of cables in three-phase distribution circuits at load currents with harmonic content
More
|
|
DIN VDE 0100-530
; VDE 0100-530:2018-06
|
2018-06
|
Low-voltage electrical installations - Part 530: Selection and erection of electrical equipment - Switchgear and controlgear
More
|
|
DIN VDE 0100-534
; VDE 0100-534:2016-10
|
2016-10
|
Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages (IEC 60364-5-53:2001/A2:2015, modified); German implementation HD 60364-5-534:2016
More
|
|
DIN VDE 0100-551
; VDE 0100-551:2017-02
|
2017-02
|
Low-voltage electrical installations - Part 5-55: Selection and erection of electrical equipment - Other equipment - Clause 551: Low-voltage generating sets (IEC 60364-5-55:2001/A2:2008 (Clause 551)); German implementation of HD 60364-5-551:2010 + Cor.:2010 + A11:2016
More
|