NA 134

VDI/DIN-Commission on Air Pollution Prevention (KRdL) - Standards Committee

Technical Report [CURRENT]

DIN CEN/TR 17078 ; DIN SPEC 33978:2017-10
Stationary source emissions - Guidance on the application of EN ISO 16911-1; German version CEN/TR 17078:2017

Title (German)

Emissionen aus stationären Quellen - Leitlinien zur Anwendung von EN ISO 16911-1; Deutsche Fassung CEN/TR 17078:2017

Procedure

Technical Report

Overview

This Technical Report provides guidelines for the application of DIN EN ISO 16911-1. It was produced in response to a request from the mirror committees of the member states to clarify certain elements of EN ISO 16911-1 and to determine how certain requirements of this standard should be interpreted. The Technical Report contains recommendations with regard to which requirements and performance characteristics are applicable to specific measurement tasks and areas of application in order to achieve uniform implementation of DIN EN ISO 16911-1. The Technical Report does not provide guidelines for the application of DIN EN ISO 16911-2. DIN EN ISO 16911-1 describes a method for determining the flow profile, the average flow rate and the volume flow rate by means of point measurements of the flow velocity. It also offers alternative methods based on the injection of tracer gas that can be used to provide routine calibration for automated flow monitoring systems; it also describes a method based on calculating process conditions. The standard provides guidance on when these alternative methods can be used. EN ISO 16911-1 requires that all flow measurements can be shown to be metrologically traceable to national or international primary standards. The method described, which has been validated in field tests on installations in Denmark and Germany, can typically achieve measurements with an uncertainty of 5 % at flow velocities of 20 m×s-1. The Technical Report has been prepared by Working Group WG 23 "Manual and automatic measurement of velocity and volumetric flow in ducts" of Technical Committee CEN/TC 264 "Air quality" with the participation of German experts appointed by VDI/DIN-Commission on Air Pollution Prevention (KRdL) - Standards Committee. The responsible committee at the national level is Subcommittee NA 134-04-01-16 UA "Volumenstrombestimmung" ("Determination of volumetric flow") of Technical Section IV "Umweltmesstechnik" ("Environmental measurement engineering") of the VDI/DIN-Commission on Air Pollution Prevention (KRdL) - Standards Committee.

Document: references other documents

Responsible national committee

NA 134-04-01-16 UA - Determination of volumetric flow  

Responsible european committee

CEN/TC 264 - Air quality  

Edition 2017-10
Original language German
Price from 97.00 €
Table of contents

Contact

Fabian Faassen

VDI-Platz 1
40468 Düsseldorf

Tel.: +49 211 6214482

Send message to contact