Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO/DIS 80601-2-61:2024); German and English version prEN ISO 80601-2-61:2024
Abstract
This document applies to the basic safety and essential performance of pulse oximeter equipment intended for use on humans, hereafter referred to as ME equipment. This includes any part necessary for normal use, including the pulse oximeter monitor, pulse oximeter probe, and probe cable extender. These requirements apply to pulse oximeter equipment, including pulse oximeter monitors, pulse oximeter probes and probe cable extenders regardless of their origin (i.e. including remanufactured products). The intended use of pulse oximeter equipment includes, but is not limited to, the estimation of arterial oxygen haemoglobin saturation and pulse rate of patients in professional healthcare institutions as well as patients in the home healthcare environment and the emergency medical services environment. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 201.11.1.2.2, IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. NOTE 2 See also IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2. This document can also be applied to ME equipment and their accessories used for compensation or alleviation of disease, injury, or disability. This document is not applicable to pulse oximeter equipment intended for use in laboratory research applications nor to oximeters that require a blood sample from the patient. This document is not applicable to pulse oximeter equipment intended solely for foetal use. This document is not applicable to remote or slave (secondary) equipment that displays SpO2 values that are located outside of the patient environment. NOTE 3 ME equipment that provides selection between diagnostic and monitoring functions is expected to meet the appropriate requirements of this document when configured for that function. This document is applicable to pulse oximeter equipment intended for use under extreme or uncontrolled environmental conditions outside the hospital environment or physician's office, such as in ambulances and air transport. Additional standards can apply pulse oximeter equipment for those environments of use. This document is a particular standard in the IEC 60601-1 and ISO and IEC 80601 series of standards.
Begin
2022-02-22
WI
00215338
Planned document number
DIN EN ISO 80601-2-61
Project number
05300501
Responsible national committee
NA 176-05-03 AA - Anaesthesia and artificial respiration
Responsible european committee
CEN/TC 215/WG 2 - Lung ventilators and related equipment
Responsible international committee
ISO/TC 121/SC 3/JWG 10 - Joint ISO/TC 121/SC 3-IEC/SC 62D WG : Oximeters
draft standard
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO/DIS 80601-2-61:2024); German and English version prEN ISO 80601-2-61:2024
2025-01